110KV Oil-immersed Power Transformer

PRODUCT OVERVIEW The bell type tank and the corrugated shell increases the strength oftank with beautiful appearance. The core is with D shape yoke with 45° miter joint. The core and tank are well

PRODUCT OVERVIEW

The bell type tank and the corrugated shell increases the strength oftank with beautiful appearance.

The core is with D shape yoke with 45° miter joint.

The core and tank are well fixed and well protected during transportation.

Reasonable winding layout method, supported by the interior and exterior strips. High-tension cardboard cylinders between coils increase the short-circuit withstand capacity.

Advanced workmanship is used, such as crimp welding technology, phase-assembly technology for winding, and cardboard process, ect.

To meet the client's needs, we can provide products of other volage ratios, vector group, and rated capacities, as listed in the table.

110KV THREE-WINDING POWER TRANSFORMERS WITH ON-LOAD TAP-CHANGER

Rated capacity(kVA) Voltage ratio(kV) Connection Symbol No-load loss(kW) No-load current(%) Full-load Loss(kW) lmpedance(%)
H.V M.V L.V Slep-down Step-up
6300 110±8×1.25%

35

37

38.5

±2×2.5%

or

±5%

6.3

6.6

10.5

11

YNd11 12 0.6 47

H-M

10.5

H-L

17-18

M-L

6.5

H-M

17-18

H-L

10.5

M-L

6.5

8000 14.4 0.6 56
10000 17.1 0.55 66
12500 20.2 0.55 78
16000 24.2 0.5 95
20000 28.6 0.5 112
25000 33,8 0.45 133
31500 40.2 0.45 157
40000 48.2 0.4 189
50000 56.9 0.4 225
63000 67.7 0.35 270

66KV DOUBLE-WINDING POWER TRANSFORMERS WITH OFF-CIRCUIT TAP CHANGER

Rated capacity(kVA) Voltage ratio(kV) Connection Symbol No-load loss(kW) No-load current(%) Full-load Loss(kW) lmpedance(%)
H.V H.V Tapping Range L.V
6300

110

121

±2×2.5%

6.3

6.6

10.5

11

YNd11 9.2 0.6 36.0 9
8000 11.2 0.6 42.7
10000 13.2 0.55 50.4
12500 15.6 0.55 59.8
16000 18.8 0.5 73.5
20000 22.0 0.5 89.1
25000 26.0 0.45 105.3
31500 30.8 0.45 126.9
40000 36.8 0.4 148.9
50000 44.0 0.4 184.5
63000 52.0 0.35 222.3

110KV THREE-WINDING POWER TRANSFORMERS WITH ON-LOAD TAP-CHANGER

Rated capacity(kVA) Voltage ratio(kV) Connection Symbol No-load loss(kW) No-load current(%) Full-load Loss(kW) lmpedance(%)
H.V H.V Tapping Range L.V
6300

63

66

69

±8x1.25%

6.6

6.6

10.5

11

YNd11 10 0.6 36.0 9
8000 12 0.6 42.7
10000 14.2 0.55 50.4
12500 16.8 0.55 59.8
16000 20.2 0.5 73.5
20000 24 0.5 89.1
25000 28.4 0.45 105.3
31500 33.7 0.45 126.9
40000 40.3 0.4 148.9
50000 47.6 0.4 184.5
63000 56.2 0.35 222.3