24kV Porcelain Housing Metal-oxide Surge Arrester
Application
Protection of medium/high voltage AC networks against both, multiple atmospheric and switching overvoltage as well as Very Fast Transients (VFT). Suitable for the protection of transformers, transformers in arc fumace applications, cables, generators, parallel to capacitor banks, and railway vehicles. Can be used mechanically as support insulator or as suspension insulator in case of application as line arrester. For indoor and outdoor installation.
Keystone
The metal-oxide surge arrester (MOSA) is the most advanced overvoltage protector in the word. Due to make the varistor of core component mainly adopt MOSA. Compared with the conventional silicone carbide arrester, this prescription of the product improves greatly the Voltage-Current(U-I) characteristic of the metal-oxide varistor and increased through-current capability at over-voltage so as to bring a radical-changes for the characteristic of the MOSA.
Under the circumstance of normal operating voltage, the current through the MOSA just on microampere degree. When suffered from overvoltage, the MOSA's excellent non-linear characteristic will make the current through the MOSA increase to several thousand ampere, While the MOSA will be under the circulating state and release overvoltage energy so as to protecting the power transmission equipments against the damage caused by the overvoltage.
Usual service condition
a) Ambient air temperature within the range of -55℃ to+50℃.
b) Altitude not exceeding 2000m.
c) Frequency of the A.C. power supply not less than 48Hz and not exceeding 62Hz.
d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage.
e) Maximum wind speed not exceeding 35m/s.
f) Earthquake intensity not exceeding 7 degrees.
Advantage
-Low residual voltage
-Long protection distance
-High energy input capacity
-Stable U-I characteristic even after multiple strokes
-Proof against ageing
-Explosion and shatter-resistant design
-Pollution resistant and UV-stable
-Housing resistant to rough handling
-Maintenance free
-Stable against shock and vibration
-High mechanical resistance
Technical Performance
The technical performance of metal-oxide surge arrester is accord with IEC60099-4, IEEE(ANSI)C62.11 and GB11032.
Y5W, Y5C, Yl0W, YI0C Series Porcelain Housing Metal-oxide Surge Arrester
Table 1-Main Technical Parameter of Porcelain Housing Metal-oxide Surge Arrester with Series Gaps
Nominal Discharge Current: 5Ka
|
Rated Voltage |
kV |
3 |
6 |
9 |
10 |
12 |
15 |
18 |
21 |
24 |
27 |
30 |
33 |
36 |
|
Nominal discharge current |
kA |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
1 |
Type |
|
Y5C-3 |
Y5C-6 |
Y5C-9 |
Y5C-10 |
Y5C-12 |
Y5C-15 |
Y5C-18 |
Y5C-21 |
Y5C-24 |
Y5C-27 |
Y5C-30 |
Y5C-33 |
Y5C-36 |
2 |
Continuous operating voltage |
kV |
2.55 |
5.10 |
7.65 |
8.40 |
10.20 |
12.70 |
15.30 |
17.00 |
19.50 |
22.00 |
24.40 |
26.70 |
29.00 |
3 |
Residual voltage at Lighting impulse 8/20μs |
kV |
9 |
18 |
27 |
30 |
36 |
45 |
54 |
63 |
72 |
81 |
90 |
99 |
108 |
4 |
Power frequency discharge voltage≥ |
kV |
5.5 |
11 |
16 |
18 |
22 |
26 |
33 |
36 |
40 |
45 |
50 |
56 |
61 |
5 |
1.2/50μs Impulse discharge voltage≤ |
kV |
9 |
18 |
27 |
30 |
36 |
45 |
54 |
63 |
72 |
81 |
90 |
99 |
108 |
6 |
2ms rectangular current withstand |
A |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
100/150 |
7 |
4/10μs high current impulse withstand |
kA |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
8 |
Housing insulation level |
|
|||||||||||||
8.1 |
-Power frequency, wet |
kV |
40 |
60 |
65 |
75 |
95 |
105 |
120 |
125 |
135 |
155 |
170 |
185 |
190 |
8.2 |
-Lightning impulse |
kV |
100 |
110 |
110 |
140 |
140 |
140 |
160 |
170 |
180 |
190 |
200 |
220 |
240 |
9 |
Creepage distance/rated voltage ratio |
mm/kV |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
Table 2 Main Technical Parameter of Porcelain Housing Metal-oxide Surge Arrester with Series Gaps
Nominal Discharge Current: 10Ka
|
Rated Voltage |
kV |
3 |
6 |
9 |
10 |
12 |
15 |
18 |
21 |
24 |
27 |
30 |
33 |
36 |
|
Nominal discharge current |
kA |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
1 |
Type |
|
Y10C-3 |
Y10C-6 |
Y10C-9 |
Y10C-10 |
Y10-12 |
Y10-15 |
Y10C-18 |
Y10C-21 |
Y10C-24 |
Y10C-27 |
Y10C-30 |
Y10C-33 |
Y10C-36 |
2 |
Continuous operating voltage |
kV |
2.55 |
5.10 |
7.65 |
8.40 |
10.20 |
12.70 |
15.30 |
17.00 |
19.50 |
22.00 |
24.40 |
26.70 |
29.00 |
3 |
Residual voltage at Lighting impulse 8/20μs |
kV |
9 |
18 |
27 |
30 |
36 |
45 |
54 |
63 |
72 |
81 |
90 |
99 |
108 |
4 |
Power frequency discharge voltage≥ |
kV |
5.5 |
11 |
16 |
18 |
22 |
26 |
33 |
36 |
40 |
45 |
50 |
56 |
61 |
5 |
1.2/50μs Impulse discharge voltage≤ |
kV |
9 |
18 |
27 |
30 |
36 |
45 |
54 |
63 |
72 |
81 |
90 |
99 |
108 |
6 |
2ms rectangular current withstand |
A |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
200/250 |
7 |
4/10μs high current impulse withstand |
kA |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
8 |
Housing insulation level |
|
|||||||||||||
8.1 |
-Power frequency, wet |
kV |
40 |
60 |
65 |
75 |
95 |
105 |
120 |
125 |
135 |
155 |
170 |
185 |
190 |
8.2 |
-Lightning impulse |
kV |
100 |
110 |
110 |
140 |
140 |
140 |
160 |
170 |
180 |
190 |
200 |
220 |
240 |
9 |
Creepage distance/rated voltage ratio |
mm/kV |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
≥25 |
Table 3 Main Technical Parameter of Porcelain Housing Metal-oxide Surge Arrester with Series Gaps
Nominal Discharge Current: 10Ka
|
Rated Voltage |
kV |
39 |
42 |
45 |
48 |
51 |
54 |
60 |
66 |
69 |
72 |
75 |
84 |
90 |
96 |
108 |
120 |
|
Nominal discharge current |
kA |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
1 |
Type |
|
Y10W-39 |
Y10W-42 |
Y10W-45 |
Y10W-48 |
Y10W-51 |
Y10W-54 |
Y10W-60 |
Y10W-66 |
Y10W-69 |
Y10W-72 |
Y10W-75 |
Y10W-84 |
Y10W-90 |
Y10W-96 |
Y10W-108 |
Y10W-120 |
2 |
Continuous operating voltage |
kV |
31.5 |
33.6 |
36.5 |
39.0 |
40.8 |
42.0 |
48.0 |
52.8 |
55.2 |
57.0 |
60.0 |
67.2 |
70.0 |
76.0 |
84.0 |
98.0 |
3 |
Residual voltage at |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1 |
Lighting impulse 8/20μs |
kV |
103 |
111 |
119 |
127 |
135 |
143 |
159 |
175 |
183 |
191 |
199 |
218 |
222 |
237 |
266 |
295 |
3.2 |
-Steep current impulse 1/10μs |
kV |
117 |
126 |
128 |
139 |
151 |
160 |
178 |
196 |
205 |
214 |
223 |
244 |
249 |
265 |
298 |
330 |
3.3 |
-Switchgear impulse 30/60μs(10kA&up) |
kV |
94 |
101 |
102 |
110 |
115 |
119 |
132 |
145 |
152 |
158 |
165 |
181 |
184 |
197 |
221 |
245 |
3.4 |
Switching surge(class 1) |
kA |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
4 |
Long duration current impulse withstand |
|
|
|||||||||||||||
4.1 |
-Line discharge class(10kA&up) |
|
1/2/3 |
|||||||||||||||
4.2 |
-2ms rectangular current withstand |
A |
400/600/1000 |
|||||||||||||||
5 |
Operating duty |
|
|
|||||||||||||||
5.1 |
-4/10μs high current impulse withstand |
kA |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
6 |
Housing insulation level |
|
|
|||||||||||||||
6.1 |
-Lightning impulse |
kV |
200 |
210 |
210 |
240 |
240 |
240 |
250 |
280 |
290 |
300 |
315 |
350 |
380 |
400 |
450 |
500 |
6.2 |
-Power frequency, wet 1 min |
kV |
100 |
110 |
110 |
140 |
140 |
140 |
160 |
170 |
180 |
190 |
200 |
220 |
240 |
250 |
280 |
320 |
7 |
Partial discharge |
pC |
<10 |
|||||||||||||||
8 |
Creepage distance/rated voltage ratio |
mm/kV |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |
≥31 |